What is CMP/FT6

Views : 1866
Author : Tony Huang
Update time : 2020-11-02 11:48:07
What is CMP/FT6

UL CMP/C.S.A FT6

UL Standard for Safety Test for Flame-Propagation and Smoke-Density Values for Electrical and Optical-Fiber Cables Used in Spaces Transporting Environmental Air. The purpose of this test is to determine whether the flame-propagation and smoke-generating characteristics of cables without raceways are within the limits specified in the National Electrical Code (NEC).

Products passing the FT6 Horizontal Flame and Smoke Test are designated FT6 in the column. This test is for cables which must pass a Horizontal Flame and Smoke Test in accordance with ANSI/NFPA Standard 262-1985 (UL-910). The maximum flame spread shall be 1.50 meters (4.92 ft.). The smoke density shall be 0.5 at peak optical density and 0.15 at maximum average optical density.
Related News
Read More >>
Why is 4.3-10 Connector so popular Why is 4.3-10 Connector so popular
Jun .08.2023
Low PIM 4.3-10 connector is becoming increasingly necessary to meet network performance goals in the latest wireless systems.
What is RF Coaxial Connector What is RF Coaxial Connector
Oct .13.2022
RF Coaxial Connector transmit RF signals, RF Coaxial Connector always connector with the same type connector, which is the opposite polarity.